Support Questionnaire

The purpose of this site is to give you an overview of all question which are helpful for us to find a solution of the support issue.

 

Contact information

If a problem regarding the USB-connect-LPWA product appears, please contact our support:

Email: support@exelonix.com

Phone: +49 351 219 71 448

 

In order to find the solution for your problem, please try to answer the following questions in your support request.

 

General

In order to take care of your support issue, the three questions should be always answered.

What is the problem?

Please give us a detailed problem description. Hereby, information about time until the problem occurred or reproducibility should be included.

What is the application?

For supporting you, we need a description of target application and information whether the hardware integration manual was considered or not.

What configuration have been done so far?

To follow-up the configuration history of the device, we need information about the configurations which have been done in the past.

No USB Connection

If you have problems to establish an USB connection to the device please answer the following questions.

Is the Device recognized by OS?

Windows 10

In windows 10, the device should be automatically detected as Data Only device as shown in the figure below.

VODEXL is recognized by Windows 10 as a data only device

Linux

See the trouble shooting part for NB-EASY

Selection of the right comport?

The VODEXL has two serial ports. However, only one port can be used for serial communication between host and device.

The other port is for diagnostic purposes only.

The serial port can be easily tested by sending an AT command to the modem.

 

Does the serial connection have the right configuration?

In order to establish a serial connection to the device, it is important to use the following serial interface configuration:

  • Baud rate: 115200

  • Data bits: 8

  • Stop bits: 1

  • Parity: none

No attach to Vodafone network

Is the SIM CHIP available?

To establish a connection to the Vodafone network, the modem of the device has to access the SIM chip.

The functionality of the SIM chip can be tested as shown below.

 

Is the SIM chip activated?

The SIM chip profile has to be activated by Vodafone, otherwise the device will be rejected (+CEREG: 2,3) by network.

 

The following figure shows an example of a scenario when the SIM chip profile is activated (+CEREG: 2,5).

Is the right MNO profile selected?

The number of bands and channels are directly addressed by MNO profiles. Hence, to connect to Vodafone network, the right MNO profiles have to selected.

The available Vodafone profiles on VODEXL are:

  • 19 (Europe)

  • 197 (Global)

For the selecting the right profile see the code examples

 

Insufficient Internet connection

Does the hardware installation follow the instruction in the hardware manual?

The RF performance of the device highly depends on the right installation. Therefore, make sure that the application follows the instruction in the hardware manual.

How good is the radio connection to the Vodafone network?

The properties of the radio connection to the Vodafone network can be tested by the following AT Commands.

 

+RSRP: the Parameter in quotation marks represent the RSRP value.

+RSRQ: the Parameter in quotation marks represent the RSRQ value.

+CSQ returns the RSSI (General Signal strength)

 

For an analysis of the radio conncetion only RSRP and RSRQ should be considered as shown in the table below.

Rating of RF connection

RSRP

RSRQ

Rating of RF connection

RSRP

RSRQ

Very good

-50 dBm .. -65 dBm

-3 dB

good

-65 dBm .. -80 dBm

-4 ..-5 dB

satisfactory

-80 dBm .. -95 dBm

-6 .. -8 dB

sufficient

-95 dBm .. -105 dBm

-9 .. -11 dB

unsatisfactory

-110 dBm ..-125 dBm

-12 .. -15 dB

not sufficient

-125 dBm ..-140 dBm

-16 .. -20 dB

 

 

Is it possible to establish a connection to a test server?

In order to establish a test connection, please follow the procedure in figure below.

 

Device shutdown

For an investigation of a any device instability issues, please answer the following questions.

Does the application follow the specification in hardware manual?

For more information please, have a look at the hardware manual. A detailed description of the application and the hardware integration are needed.

How long does the device work until the shut down takes place?

For a detailed evaluation of the instability issues, information like mean time to failure (here shutdown) are of great interest.

Does the shut down happens before or after the first attach?

Sometimes information from the network can lead to a configuration which could be misinterpreted as a shutdown (e.g. deep sleep. See power configuration for more details).

Does the device shut down periodically?

Hereby, the reason could be misconfiguration or cyclic overload of the device. For that reason, a description of the application would be necessary for a deeper investigation.

How long is the interval between the shutdowns?

Does the device response between the shutdowns?

What are the power save configurations?

When the device periodically shuts down after the first attach to the network, the power save configuration could cause to a cyclic deep sleep of the device, which often is misinterpreted as cyclic shutdown.

This can be verified by disabling the power save functionality of the modem as shown below.