Working und Storage Conditions

Parameter

Minimum Value

Maximum Value

Unit

Operating temperature

-10

+55

°C

Storage temperature

-25

+70

°C

Humidity Range

5

95

%

Integration

The 5G SENS is an industrial product and may only be used in an industrial environment. Furthermore, the use within a distance of less than 20 cm to the human body is not allowed.

This device uses radio technologies to communicate with the environment. Mainly the internal antenna causes a good RF performance. However, the RF performance will degrade by a faulty application. In addition to a minimum distance of 20 cm to the human body, you should avoid larger metal surfaces in the device's immediate vicinity. Placing the device on such a surface could negatively affect the transmitting and receiving power and changes the radiation pattern. Even humidity will cause an attenuating effect. Use the device in free space for optimal conditions regarding the RF performance.

The 5G SENS is not a medical device. That means the 5G SENS is not intended for a medical purpose, to be used directly on humans.

Noise from an active USB-Connection

The USB connection is a high-speed data interface with a clock, which might also cause interfering RF noise. The clock noise shows up at multiples of 480 MHz since the USB clock is 48 MHz * 10 = 480 MBit/s. This type of RF noise is commonly seen at 480/960 MHz on USB powered wireless devices and might affect the performance of the 5G SENS in the lower frequency bands.

Therefore the following is recommended:

  • Ensure proper EMC shielding of the USB-Connection

Proper Measurement Results

The devices design is tested for proper measurement results within the given ranges in the data sheet. Please note that each device has a measurement settling time which increases towards the edges of the measurement range.

For larger changes of humidity values please allow long settling times (hours to days in the extreme case).

For temperature measurements please note the the device is very sensitive to the environment. Small differences in placements in the environment might cause more effect to the temperature than expected.

Note, the air pressure is dependent of the measurement hight.

Note, for GNSS values that theses are dependent the GNSS technology, and the connectivity to according satellites.

Software Updates

By continuing to use this device, you indicate that you have read and agree to the following content:
In order to provide better service, this device will automatically check for/obtain software update information from the vendor and its partners after connecting to the Internet. This process may use mobile data and requires access to your device's unique identifier to check whether your device needs to be updated. Note that neither the Vendor nor its partners will use the information for the purposes of personally identifying you, this is only used for managing software updates.