General Information
Product Marketing Name | USB Connect 4G - EU |
---|---|
Revision | 20-004-1.3-EU |
Manufacturer | exelonix GmbH Washingtonstraße 16/16a 01139 Dresden Germany |
Description
The USB Connect 4G - EU is a USB-Device for cellular communication and supports the LTE CAT 4 standard
The device is connected to the host device by a USB Type A interface, which supplies the USB-Device with power and transmit/receive data.
Supported LTE Bands
LTE Band | Max. Output Power (dBm) | Frequency (MHz) | Uplink (MHz) | Downlink (MHz) | Channels | Product Variant |
---|---|---|---|---|---|---|
1 | 23 dBm | 2100 | 1920 – 1980 | 2110 – 2170 | Tx: 18000 - 18599 | AP, EU |
2 | 23 dBm | 1900 | 1850-1910 | 1930-1990 | Tx: 18600 - 19199 | NF |
3 | 23 dBm | 1800 | 1710-1785 | 1805-1880 | Tx: 19200 - 19949 | AP, EU |
4 | 23 dBm | 1700 | 1710-1755 | 2110-2155 | Tx: 19950 - 20399 | NF |
5 | 23 dBm | 850 | 824-849 | 869-894 | Tx: 20400 - 20649 | AP |
7 | 23 dBm | 2600 | 2500 – 2570 | 2620 – 2690 | Tx: 20750 - 21449 | EU |
8 | 23 dBm | 900 | 880-915 | 925-960 | Tx: 21450 - 21799 | AP, EU |
9 | 23 dBm | 1700 | 1749.9 - 1784.9 | 1844.9 - 1879.9 | Tx: 21800 - 2149 | AP |
12 | 23 dBm | 700 | 699-716 | 729-746 | Tx: 23010 - 23179 | NF |
19 | 23 dBm | 850 | 830 – 845 | 875 – 890 | Tx: 24000 - 24149 | AP |
20 | 23 dBm | 800 | 832-862 | 791-821 | Tx: 24150 - 24449 | EU |
28 | 23 dBm | 700 | 758 - 803 | 703 - 748 | Tx: 27210 - 27659 | AP |
28A | 23 dBm | 700 | 703-733 | 758-788 | Tx: 27210 - 27510 | EU |
B66 | 23 dBm | 1700 | 1710 – 1780 | 2110 – 2200 | Tx: 131972- 132671 | NF |
Working und Storage Conditions
Parameter | Minimum Value | Maximum Value | Unit |
---|---|---|---|
Operating temperature | -20 | +55 | °C |
Storage temperature | -20 | +70 | °C |
Humidity Range | 5 | 95 | % |
Electrical Characteristics
Consumption
Mode | Value |
---|---|
Switched OFF | 25 µA |
Idle Mode (No Call) | max. 15 mA |
Operating Mode | 200 - 600 mA |
USB Voltage Range | 4,8 V - 5,5 V (normally 5 V) |
Get started with USB Connect 4G - EU
Preparations & Power Up
Install the drivers for Windows/Linux operating system on your host device→ https://www.telit.com/evkevb-drivers/
Plug the USB Connect 4G into the USB Type A socket of the host device.
Make sure that the distance from your body to the USB Connect 4G is greater than 20 cm.
If the USB socket of the host device is active, the USB Connect 4G starts automatically.
Now you can identify the COM port of the USB Connect 4G - XX and send AT commands to unlock the at command interface. Therefore you need to send (ask manufacturer for password):
AT#SECIFAUTH=XXXXXXXXXX
Power Down
The power supply should not be suddenly interrupted before the shutdown procedure has been carried out
First set the following setting via the AT command interface (e.g. via the AT controller):
AT#GPIO=10,1,1
Now the command
AT#SHDN
can be sent to shut down the USB Connect 4G.
After about 15s you can disconnect the USB Connect 4G from the host device.
Operating
AT commands can be used during operation to establish a network connection. You can find an overview of the AT commands in the AT commands reference guide from Telit: https://www.telit.com/m2m-iot-products/cellular-modules/standard-industrial-grade/xe910-family/#LE910Cx-downloads
Compliances
General
It is only allowed to be used in products where the USB device itself is placed to a location which guarantees a distance of >20cm from the user (user body). The bulky dimensions of the enclosure of the USB device (H x L x W = 24 x 85 x 57mm) already indicate that usage in a normal laptop is not intended and would be inconvenient. The requirements for the location and the according limitations to locations with distance of >20cm to the user are clearly indicated with the USB device as required by law.
The USB Connect 4G - XX is not a medical device. That means the USB Connect 4G - XX is not intended for a medical purpose, to be used directly on humans.
As already described, the stick contains the LE910C4-XX module from Telit. The compliance information statements for this module can be found at https://www.telit.com/m2m-iot-products/cellular-modules/standard-industrial-grade/xe910-family/#LE910Cx-downloads
USB Connect 4G - NF
ISED Certification
This device will be registered with Innovation, Science and Economic Development Canada under the following number:
IC: 5131A-LE910CxNF
This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions:
This device may not cause interference;
This device must accept any interference, including interference that may cause undesired operation of the device.
FCC Certification
This device contains will be registered with the Federal Communications Commission under the following number:
Contains FCC ID: RI7LE910CXNF
No changes shall be made to the equipment without the manufacturer’s permission as this may void the user’s authority to operate the equipment. Changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
PTCRB
The product manufactured by Exelonix GmbH is in compliance with PTCRB.
For further information you can visit this page : https://www.ptcrb.com/
USB Connect 4G - EU
CE Certification
Hereby, exelonix GmbH declares that the radio equipment type USB Connect 4G - EU is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: https://www.exelonix.com/de/
WEEE
Exelonix GmbH fully endorses the environmental objectives of the WEEE. All electronic products must be collected and sent to approved operators for safe disposal of electronic equipment.
USB Connect 4G - AP
Australia
This device is in compliance with the Australian "Radiocommunications Act 1992" and, therefore, it is labeled according to the "Radiocommunications (Compliance labeling – Devices) Notice”.
Japan
This device is granted pursuant to the Japanese Radio Law (電波法).
This device should not be modified (otherwise the granted designation number will become invalid).