General Information

Product Marketing Name

USB Connect 4G - EU

Revision

20-004-1.3-EU

Manufacturer

exelonix GmbH

Washingtonstraße 16/16a

01139 Dresden

Germany

Description

The USB Connect 4G - EU is a USB device for cellular communication and supports the LTE CAT 4 standard.

The device is connected to the host device by a USB Type A interface, which supplies the USB device with power and transmit/receive data. When your device is in use, the system handling your connection controls the power level at which your device transmits.

Supported LTE Bands

LTE Band

Max. Output Power (dBm)

Frequency

(MHz)

Uplink

(MHz)

Downlink

(MHz)

Channels

1

23 dBm

2100

1920 – 1980

2110 – 2170

Tx: 18000 - 18599
Rx: 0 - 599

3

23 dBm

1800

1710-1785

1805-1880

Tx: 19200 - 19949
Rx: 1200 - 1949

7

23 dBm

2600

2500 – 2570

2620 – 2690

Tx: 20750 - 21449
Rx: 2750 - 3449

8

23 dBm

900

880-915

925-960

Tx: 21450 - 21799
Rx: 3450 - 3799

20

23 dBm

800

832-862

791-821

Tx: 24150 - 24449
Rx: 6150 - 6449

28A

23 dBm

700

703-733

758-788

Tx: 27210 - 27510
Rx: 9210 - 9510

Working und Storage Conditions

Parameter

Minimum Value

Maximum Value

Unit

Operating temperature

-20

+55

°C

Storage temperature

-20

+70

°C

Humidity Range

5

95

%

Electrical Characteristics

Consumption

Mode

Value

Switched OFF

25 µA

Idle Mode (No Call)

max. 15 mA

Operating Mode

200 - 600 mA

USB Voltage Range

4,8 V - 5,5 V (normally 5 V)

Get started with USB Connect 4G - EU

Preparations & Power Up

  1. Install the drivers for Windows/Linux operating system on your host device.→ https://www.telit.com/evkevb-drivers/

  2. Plug in the USB Connect 4G into the USB Type A socket of the host device.

  3. Make sure that the distance from your body to the USB Connect 4G is larger than 20 cm.

  4. If the USB socket of the host device is active, the USB Connect 4G starts automatically.

  5. Now you can identify the COM port of the USB Connect 4G - EU and send AT commands to unlock the AT command interface. For this, you need to send the following command (ask manufacturer for password):

    AT#SECIFAUTH=XXXXXXXXXX

Power Down

To avoid any damage to the USB device , the power supply must not be interrupted before the shutdown procedure has been fully carried out.

  1. First set the following setting via the AT command interface (e.g. via the AT controller):

    AT#GPIO=10,1,1
  2. Now the command

    AT#SHDN

    can be sent to shut down the USB Connect 4G.

  3. After 15 sec you can safely disconnect the USB Connect 4G from the host device.

Operating

AT commands can be used during operation to establish a network connection. Please find an overview in the AT commands reference guide from Telit: https://www.telit.com/m2m-iot-products/cellular-modules/standard-industrial-grade/xe910-family/#LE910Cx-downloads

Compliances

General

Please consult User Manual

To ensure compliance with RF exposure guidelines the device must be used with a minimum of 20cm separation from the body. Failure to observe these instructions could result in your RF exposure exceeding the relevant guideline limits.

The USB Connect 4G - EU is not a medical device, that means the USB Connect 4G - XX is not intended for a medical purpose, to be used directly on humans.

The USB device contains the LE910C4-EU module from Telit. The compliance information statements for this module can be found at https://www.telit.com/m2m-iot-products/cellular-modules/standard-industrial-grade/xe910-family/#LE910Cx-downloads

CE Certification

Hereby, exelonix GmbH declares that the radio equipment type USB Connect 4G - EU is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: https://www.exelonix.com/de/

WEEE

Exelonix GmbH fully endorses the environmental objectives of the WEEE. All electronic products must be collected and sent to approved operators for safe disposal of electronic equipment.

Safety Instrustions

Driving

Full attention must be given to driving at all times in order to reduce the risk of an accident. Using this device while driving causes distraction and can lead to an accident. You must comply with local laws and regulations restricting the use of wireless devices while driving.