pytime

Denotes a dead time after a motion was detected. Motions of the device within the dead time don't trigger a new transfer of positioning information.

Value range

  • Must be an integer

  • The pytime value is specified in minutes

Note
  • If pmode is set to 1, this setting has no effect

Example

Drawio
mVer2
zoom1
simple0
inComment0
custContentId3859873802
pageId3530981377
lbox1
diagramDisplayNameUntitled Diagram-1696860677087.drawio
contentVer1
revision1
baseUrlhttps://exelonix.atlassian.net/wiki
diagramNameUntitled Diagram-1696860677087.drawio
pCenter0
width1015
links
tbstyle
height261

cid

A custom identifier that will be attached to all telemetry records of the device. After a value was assigned to a device, it can be used instead of the device ID to analyse telemetry data via the Exelonix backend.

Value range

  • Must be a string with a maximum length of 32 characters

  • Only characters a-zA-Z0-9.- are permitted

Note
  • The same value can be assigned to multiple devices. You need to ensure uniqueness across multiple devices yourself if this is required.