General Information

Product Marketing Name

USB Connect 4G - EU

Revision

20-004-1.3-EU

Manufacturer

exelonix GmbH

Washingtonstraße 16/16a

01139 Dresden

Germany

Description

...

The USB Connect 4G - EU is a USB -Device device for cellular communication and supports the LTE CAT 4 standard.

The device is connected to the host device by a USB Type A interface, which supplies the USB -Device device with power and transmit/receive data.

Supported LTE Bands

LTE Band

Max. Output Power (dBm)

Frequency

(MHz)

Uplink

(MHz)

Downlink

(MHz)

Channels

Product Variant

1

23 dBm

2100

1920 – 1980

2110 – 2170

Tx: 18000 - 18599
Rx: 0 - 599

AP, EU

2

23 dBm

1900

1850-1910

1930-1990

Tx: 18600 - 19199
Rx: 600 - 1199

NF

3

23 dBm

1800

1710-1785

1805-1880

Tx: 19200 - 19949
Rx: 1200 - 1949

AP, EU

4

23 dBm

1700

1710-1755

2110-2155

Tx: 19950 - 20399
Rx: 1950 - 2399

NF

5

23 dBm

850

824-849

869-894

Tx: 20400 - 20649
Rx: 2400 - 2649

AP

7

23 dBm

2600

2500 – 2570

2620 – 2690

Tx: 20750 - 21449
Rx: 2750 - 3449EU

8

23 dBm

900

880-915

925-960

Tx: 21450 - 21799
Rx: 3450 - 3799

AP, EU

9

23 dBm

1700

1749.9 - 1784.9

1844.9 - 1879.9

Tx: 21800 - 2149
Rx: 3800 - 4149

AP

12

23 dBm

700

699-716

729-746

Tx: 23010 - 23179
Rx: 5010 - 5179

NF

19

23 dBm

850

830 – 845

875 – 890

Tx: 24000 - 24149
Rx: 6000 - 6149

AP

20

23 dBm

800

832-862

791-821

Tx: 24150 - 24449
Rx: 6150 - 6449

EU

28

23 dBm

700

758 - 803

703 - 748

Tx: 27210 - 27659
Rx: 9210 - 9659

AP

28A

23 dBm

700

703-733

758-788

Tx: 27210 - 27510
Rx: 9210 - 9510EU

B66

23 dBm

1700

1710 – 1780

2110 – 2200

Tx: 131972- 132671
Rx: 66436-67335

NF

Working und Storage Conditions

Parameter

Minimum Value

Maximum Value

Unit

Operating temperature

-20

+55

°C

Storage temperature

-20

+70

°C

Humidity Range

5

95

%

Electrical Characteristics

...

Mode

Value

Switched OFF

25 µA

Idle Mode (No Call)

max. 15 mA

Operating Mode

200 - 600 mA

USB Voltage Range

4,8 V - 5,5 V (normally 5 V)

...

Getting started with USB Connect 4G - EU

Preparations & Power Up

  1. Install the drivers for Windows/Linux operating system on your host

...

  1. device.→ https://www.telit.com/evkevb-drivers/

  2. Plug in the USB Connect 4G into the USB Type A socket of the host device.

  3. Make sure that the distance from your body to the USB Connect 4G is

...

  1. larger than 20 cm.

  2. If the USB socket of the host device is active, the USB Connect 4G starts automatically.

  3. Now you can identify the COM port of the USB Connect 4G -

...

  1. EU and send AT commands to unlock the

...

  1. AT command interface.

...

  1. For this, you need to send the following command (ask manufacturer for password):

    Code Block
    AT#SECIFAUTH=XXXXXXXXXX

Power Down

Note

The To avoid any damage to the USB device , the power supply should must not be suddenly interrupted before the shutdown procedure has been fully carried out.

  1. First set the following setting via the AT command interface (e.g. via the AT controller):

    Code Block
    AT#GPIO=10,1,1
  2. Now the command

    Code Block
    AT#SHDN

    can be sent to shut down the USB Connect 4G.

  3. After

...

  1. 15 sec you can safely disconnect the USB Connect 4G from the host device.

Operating

AT commands can be used during operation to establish a network connection. You can Please find an overview of the AT commands in the AT commands reference guide from Telit: https://www.telit.com/m2m-iot-products/cellular-modules/standard-industrial-grade/xe910-family/#LE910Cx-downloads

Compliances

General

...

Note

Please consult User Manual

To ensure compliance with RF exposure guidelines the device must be used with a minimum of 20cm separation from the body. Failure to observe these instructions could result in your RF exposure exceeding the relevant guideline limits. The requirements for the location and the according limitations to locations with distance of >20cm minimum 20cm to the user are clearly indicated with the USB device as required by law. The USB Connect 4G - XX is not a medical device. That means the USB Connect 4G - XX is not intended for a medical purpose, to be used directly on humans.As already described, the stick contains the LE910C4-XX device is strictly for industrial use/application and installed in industrial environment. This device is not intended for remote access via LTE. This also includes firmware updates and changes to the radio settings via LTE. If a firmware update is necessary, please contact the manufacturer.

The USB device contains the LE910C4-EU module from Telit. The compliance information statements for this module can be found at https://www.telit.com/m2m-iot-products/cellular-modules/standard-industrial-grade/xe910-family/#LE910Cx-downloads

USB Connect 4G - NF

ISED Certification

This device will be registered with Innovation, Science and Economic Development Canada under the following number:

IC: 5131A-LE910CxNF

This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions:

  • This device may not cause interference;

  • This device must accept any interference, including interference that may cause undesired operation of the device.

...

This device contains will be registered with the Federal Communications Commission under the following number:

Contains FCC ID: RI7LE910CXNF

  • No changes shall be made to the equipment without the manufacturer’s permission as this may void the user’s authority to operate the equipment. Changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment

  • This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

  • This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

PTCRB

The product manufactured by Exelonix GmbH is in compliance with PTCRB.

For further information you can visit this page : https://www.ptcrb.com/

USB Connect 4G - EU

CE Certification

Hereby, exelonix GmbH declares that the radio equipment type USB Connect 4G - EU is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: https://www.exelonix.com/de/

WEEE

Exelonix GmbH fully endorses the environmental objectives of the WEEE. All electronic products must be collected and sent to approved operators for safe disposal of electronic equipment.

Safety Instructions

RF Exposure

When your device is in use, the system handling your connection controls the power level at which your device transmits.

Distraction

Driving

Full attention must be given to driving at all times in order to reduce the risk of an accident. Using this device while driving causes distraction and can lead to an accident. You must comply with local laws and regulations restricting the use of wireless devices while driving.

Operating machinery

Full attention must be given to operating the machinery in order to reduce the risk of an accident.

Product Handling

You alone are responsible for how you use your device and any consequences of its use.

You must always switch off your device wherever the use of a mobile phone is prohibited. If your device has clip-on covers, do not use it without the covers attached and do not remove or change them while using the device.

USB Connect 4G - AP

Australia

This device is in compliance with the Australian "Radiocommunications Act 1992" and, therefore, it is labeled according to the "Radiocommunications (Compliance labeling – Devices) Notice”.

Japan

This device is granted pursuant to the Japanese Radio Law (電波法).

This device should not be modified (otherwise the granted designation number will become invalid).Use of your device is subject to safety measures designed to protect users and their environment.

  • Always treat your device and its accessories with care and keep it in a clean and dust-free place.

  • Do not expose your device or its accessories to open flames or lit tobacco products.

  • Do not expose your device or its accessories to liquid, moisture or high humidity.

  • Do not drop, throw or try to bend your device or its accessories.

  • Do not paint your device or its accessories.

  • Do not attempt to disassemble your device or its accessories: only authorised personnel must do so.

  • Do not expose your device or its accessories to extreme temperatures, minimum -20 and maximum +55 degrees Celsius.

  • Please check local regulations for disposal of electronic products.

Emergency Situations

This device, like any wireless device, operates using radio signals, which cannot guarantee connection in all conditions. Therefore, you must never rely solely on any wireless device for emergency communications.

Device Heating

Your device may become warm during normal use.

Electrical Safety

Accessories

Only use approved accessories. Do not connect with incompatible products or accessories.

Faulty and Damaged Products

Do not attempt to disassemble the device or its accessory. Only qualified personnel must service or repair the device or its accessory. If your device or its accessory has been submerged in water, punctured, or subjected to a severe fall, do not use it until you have taken it to be checked at an authorised service centre.

Interference

Care must be taken when using the device in close proximity to personal medical devices, such as pacemakers and hearing aids.

Pacemakers

Pacemaker manufacturers recommend that a minimum separation of 15 cm be maintained between a device and a pacemaker to avoid potential interference with the pacemaker.

Hearing Aids

People with hearing aids or other cochlear implants may experience interfering noises when using wireless devices or when one is nearby.

The level of interference will depend on the type of hearing device and the distance from the interference source, increasing the separation between them may reduce the interference. You may also consult your hearing aid manufacturer to discuss alternatives.

Medical devices

Please consult your doctor and the device manufacturer to determine if operation of your device may interfere with the operation of your medical device.

Aircraft

Switch off your wireless device whenever you are instructed to do so by airport or airline staff. Consult the airline staff about the use of wireless devices on board the aircraft. If your device offers a ‘flight mode’ this must be enabled prior to boarding an aircraft.

Explosive environments

Petrol stations and explosive atmospheres

In locations with potentially explosive atmospheres, obey all posted signs to turn off wireless devices such as your device or other radio equipment.

Areas with potentially explosive atmospheres include fuelling areas, below decks on boats, fuel or chemical transfer or storage facilities, areas where the air contains chemicals or particles, such as grain, dust, or metal powders.

Blasting Caps and Areas

Turn off your device or wireless device when in a blasting area or in areas posted turn off “two-way radios” or “electronic devices” to avoid interfering with blasting operations.

Frequency Bands and Power

(a) Frequency bands in which the radio equipment operates: Some bands may not be available in all countries or all areas. Please contact the local carrier for more details.

(b) Maximum radio-frequency power transmitted in the frequency bands in which the radio equipment operates: The maximum power for all bands is less than the highest limit value specified in the related Harmonized Standard.

The frequency bands and transmitting power (radiated and/or conducted) nominal limits applicable to this radio equipment are as follows:

1, 3, 7, 8, 20, 28A: 23 dBm.

Software Information

The product software version is 25.20.678