  • Design Guide
  • ESD Precautions
    • PCB Design for the Host
      • Use a four-layer or six-layer PCB but not a two-layer PCB?
      • Use a large-capacity ceramic bypass capacitor and decoupling capacitor on the MS2372h
        power supply. Place them within 30 mm from the connector. The PCB cable routing
        width must be at least 20 mm. Deploy dedicated power cable plane and ground or
        integrated power and ground grid. Use a transient voltage suppressor (TVS) for external
        electrical overstress (EOS) protection that has a peak power larger than 100 W at 8/20
        μs.
      • If the signal cable length is larger than 300 mm (12 inches), ground all sides of the signal
        cables. Drill holes on the grounds to connect them to the main ground every 100 mm.
      • When connecting the host to the MS2372h, ensure the grounding reliability.
      • Use TVSs at the joint between the MS2372h and the host. The TVS on the male
        connector must have a parasitic capacitance less than 1 pF while the TVS on the power
        supply must have a peak power larger than 100 W at 8/20 μs.
    • Cover Design for the Host
      • The MS2372h comes with ESD protection. The SIM card and connector area are most
        vulnerable.
      • Since the SIM card slot is highly vulnerable to ESD, it should be covered by mechanical part
        to prevent direct touch by users.
  • Electrical and Reliability Features
  • LED blinking pattern:
  •      RED LED on : Device is powered on
  •      GREEN LED on: device is registered in the network
  •      GREEN LED and RED LED alternating : device is registered in the network and roaming (this will be the usual pattern)