pxtime

Denotes the length of the intervals after which the device sends a telemetry message

Value range

  • Must be an integer

  • The pxtime value is specified in minutes and must be smaller or equal to 1440

Note
  • If pmode is set to 0, this setting has no effect

Example

Drawio
zoom1
simple0
inComment0
custContentId3512926225
pageId3511812097
lbox1
diagramDisplayNamepxtime.drawio
contentVer4
revision4
baseUrlhttps://exelonix.atlassian.net/wiki
diagramNamepxtime.drawio
pCenter0
width1000
links
tbstyle
height271

cid

A custom identifier that will be attached to all telemetry records of the device. After a value was assigned to a device, it can be used instead of the device ID to analyse telemetry data via the Exelonix backend.

Value range

  • Must be a string with a maximum length of 32 characters

  • Only characters a-zA-Z0-9.- are permitted

Note
  • The same value can be assigned to multiple devices. You need to ensure uniqueness across multiple devices yourself if this is required.

pcollect

Instruct the device to gather multiple measurements locally and send them collectively afterwards via the mobile network.

Value range

  • Must be an integer

  • Minimum value: 9

  • Maximum value: 86400

Note
  • The pcollectfunctionality is deactivated by default, and in this case, the device will report value 0 for this parameter.

  • Note that it is currently impossible to deactivate the pcollect mechanism once it has been activated.

gnss-force-next-time

Force the device to update its GNSS position information the next time readings are collected.

Value range

  • Must be an integer

  • Valid values

    • 0 — Don’t force an update of the GNSS position information

    • 1 — Force an update of the GNSS position information

Note
  • When the device receives no GNSS signal, the position information won’t be updated, regardless of this setting.

  • The device will automatically reset this parameter to 0 after it executed the forced update.

gnss-trigger

Configure the device to update GNSS position information only after every X readings are collected.

Value range

  • Must be an integer

  • Minimum value: 0

  • Maximum value: 99999