Product Marketing Name | USB Connect 4G - XXNF | ||
---|---|---|---|
Revision | 20-004-1.3-XX | Product Variants | XX = EU, NF or AP |
Manufacturer | exelonix GmbH Washingtonstraße 16/16a 01139 Dresden Germany |
Description
...
The USB Connect 4G - XX NF is a USB-Device for cellular communication and supports the LTE CAT 4 standard
...
Electrical Characteristics
...
Mode | Value |
---|---|
Switched OFF | 25 µA |
Idle Mode (No Call) | max. 15 mA |
Operating Mode | 200 - 600 mA |
USB Voltage Range | 4,8 V - 5,5 V (normally 5 V) |
Getting started with USB Connect 4G -
...
NF
Preparations & Power Up
Install the drivers for Windows/Linux operating system on your host device→ https://www.telit.com/evkevb-drivers/
Plug the USB Connect 4G into the USB Type A socket of the host device.
Make sure that the distance from your body to the USB Connect 4G is greater than 20 cm.
If the USB socket of the host device is active, the USB Connect 4G starts automatically.
Now you can identify the COM port of the USB Connect 4G - XX NF and send AT commands to unlock the at command interface. Therefore you need to send (ask manufacturer for password):
Code Block AT#SECIFAUTH=XXXXXXXXXX
...